RFT 'Could not create the view: ' 解决办法

来源:互联网 发布:linux中的tar命令 编辑:程序博客网 时间:2024/06/05 03:44

Could not create the view: Plug-in com.rational.test.ft.wswplugin was unable to load class com.rational.test.ft.wswplugin.project.TestExplorerPart.

Refer link:  http://www-01.ibm.com/support/docview.wss?uid=swg21293066

Problem(Abstract)

When you start IBM® Rational® Functional Tester (RFT), you get the error message "Unable to create view".

Symptom

The full error message is:

Unable to create view: Plug-in com.rational.test.ft.wswplugin was unable to load class com.rational.test.ft.wswplugin.project.TestExplorerPart.

The error message might display when you start RFT for the first time after the installation.




Cause

The cause is unknown.

Resolving the problem

To resolve the problem, you can try to start RFT with the -clean option. This option removes the cache of the already loaded plug-in jar files and builds a new configuration. For more information about this option you can read technote 1212752:

What the -clean option does in Rational Application Developer

To run the option from the command line, enter it as below:


"C:\Program Files\IBM\SDP70\eclipse.exe" -product com.ibm.rational.rft.product.ide -clean


Alternately, change the shortcut in the Programs Menu. Append to Properties > Target the string-clean option.

Notes:

If the -clean option does not improve the situation, you might consider to do a clean install. The following technotes describe the clean uninstallation of RFT. 
http://www-01.ibm.com/support/docview.wss?uid=swg21212752