hbase 结点之间时间不一致造成regionserver启动失败

来源:互联网 发布:mac怎么看群相册 编辑:程序博客网 时间:2024/05/14 02:55

  http://sishuok.com/forum/blogPost/list/5411.html


Caused by: org.apache.hadoop.ipc.RemoteException: org.apache.hadoop.hbase.ClockOutOfSyncException: Server s3,60020,1304927875246 has been rejected; Reported time is too far out of sync with master.  Time difference of 41450ms > max allowed of 30000ms

1.方案1
在hbase-site.xml添加配置
<property>
        <name>hbase.master.maxclockskew</name>
        <value>180000</value>
        <description>Time difference of regionserver from master</description>
 </property>

2.方案2
修改各结点时间,使其误差在30s内

 

转自:http://hbluojiahui.blog.163.com/blog/static/310647672011427103841280/

 

我写了一个同步时间的shell脚本

 

 

Java代码    收藏代码
  1. #!/bin/bash  
  2. echo "start"  
  3. for ((i=211;i<=218;i++))  
  4. do  
  5.   
  6. #ssh 192.168.5.${i} 'date 110415402010; clock -w'  
  7. ssh 192.168.5.$i 'date -s "2011-05-10 10:44:00"; clock -w'  
  8. #ssh 192.168.210.${machine} 'clock -w'  
  9. done  
  10. echo "complete"  

原创粉丝点击