Serial Programming Guide for POSIX Operating Systems

来源:互联网 发布:鸟哥的linux私房菜chm 编辑:程序博客网 时间:2024/05/31 06:21


    Introduction 

    Chapter 1, Basics of Serial Communications
    • What Are Serial Communications?
    • What Is RS-232?
      • Signal Definitions
    • Asynchronous Communications
      • What Are Full Duplex and Half Duplex?
      • Flow Control
      • What Is a Break?
    • Synchronous Communications
    • Accessing Serial Ports
      • Serial Port Files
      • Opening a Serial Port
      • Writing Data to the Port
      • Reading Data from the Port
      • Closing a Serial Port
    Chapter 2, Configuring the Serial Port
    • The POSIX Terminal Interface
      • Control Options
      • Local Options
      • Input Options
      • Output Options
      • Control Characters
    Chapter 3, MODEM Communications
    • What Is a MODEM?
    • Communicating With a MODEM
      • Standard MODEM Commands
      • Common MODEM Communication Problems
    Chapter 4, Advanced Serial Programming
    • Serial Port IOCTLs
      • Getting the Control Signals
      • Setting the Control Signals
      • Getting the Number of Bytes Available
    • Selecting Input from a Serial Port
      • The SELECT System Call
      • Using the SELECT System Call
      • Using SELECT with the X Intrinsics Library
    Appendix A, Pinouts
    • RS-232 Pinouts
    • RS-422 Pinouts
    • RS-574 (IBM PC/AT) Pinouts
    • SGI Pinouts
    Appendix B, ASCII Control Codes
    • Control Codes

    Introduction

    The Serial Programming Guide for POSIX Operating Systems will teach you how to successfully, efficiently, and portably program the serial ports on your UNIX® workstation or PC. Each chapter provides programming examples that use the POSIX (Portable Standard for UNIX) terminal control functions and should work with very few modifications under IRIX®, HP-UX, SunOS®, Solaris®, Digital UNIX®, Linux®, and most other UNIX operating systems. The biggest difference between operating systems that you will find is the filenames used for serial port device and lock files.

    This guide is organized into the following chapters and appendices:

    • Chapter 1, Basics of Serial Programming
    • Chapter 2, Configuring the Serial Port
    • Chapter 3, Talking to MODEMs
    • Chapter 4, Advanced Serial Programming
    • Appendix A, RS-232 Pinouts
    • Appendix B, ASCII Control Codes

    Chapter 1, Basics of Serial Communications

    This chapter introduces serial communications, RS-232 and other standards that are used on most computers as well as how to access a serial port from a C program.

    What Are Serial Communications?

    Computers transfer information (data) one or more bits at a time. Serial refers to the transfer of data one bit at a time. Serial communications include most network devices, keyboards, mice, MODEMs, and terminals.

    When doing serial communications each word (i.e. byte or character) of data you send or receive is sent one bit at a time. Each bit is either on oroff. The terms you'll hear sometimes are mark for the on state and space for the off state.

    The speed of the serial data is most often expressed as bits-per-second ("bps") or baudot rate ("baud"). This just represents the number of ones and zeroes that can be sent in one second. Back at the dawn of the computer age, 300 baud was considered fast, but today computers can handle RS-232 speeds as high as 430,800 baud! When the baud rate exceeds 1,000, you'll usually see the rate shown in kilo baud, or kbps (e.g. 9.6k, 19.2k, etc). For rates above 1,000,000 that rate is shown in megabaud, or Mbps (e.g. 1.5Mbps).

    When referring to serial devices or ports, they are either labeled as Data Communications Equipment ("DCE") or Data Terminal Equipment ("DTE"). The difference between these is simple - every signal pair, like transmit and receive, is swapped. When connecting two DTE or two DCE interfaces together, a serial null-MODEM cable or adapter is used that swaps the signal pairs.

    What Is RS-232?

    RS-232 is a standard electrical interface for serial communications defined by the Electronic Industries Association ("EIA"). RS-232 actually comes in 3 different flavors (A, B, and C) with each one defining a different voltage range for the on and off levels. The most commonly used variety is RS-232C, which defines a mark (on) bit as a voltage between -3V and -12V and a space (off) bit as a voltage between +3V and +12V. The RS-232C specification says these signals can go about 25 feet (8m) before they become unusable. You can usually send signals a bit farther than this as long as the baud is low enough.

    Besides wires for incoming and outgoing data, there are others that provide timing, status, and handshaking:

    Table 1 - RS-232 Pin AssignmentsPinDescriptionPinDescriptionPinDescriptionPinDescriptionPinDescription1Earth Ground6DSR - Data Set Ready11Unassigned16Secondary RXD21Signal Quality Detect2TXD - Transmitted Data7GND - Logic Ground12Secondary DCD17Receiver Clock22Ring Detect3RXD - Received Data8DCD - Data Carrier Detect13Secondary CTS18Unassigned23Data Rate Select4RTS - Request To Send9Reserved14Secondary TXD19Secondary RTS24Transmit Clock5CTS - Clear To Send10Reserved15Transmit Clock20DTR - Data Terminal Ready25Unassigned

    Two standards for serial interfaces you may also see are RS-422 and RS-574. RS-422 uses lower voltages and differential signals to allow cable lengths up to about 1000ft (300m). RS-574 defines the 9-pin PC serial connector and voltages.

    Signal Definitions

    The RS-232 standard defines some 18 different signals for serial communications. Of these, only six are generally available in the UNIX environment.

    GND - Logic Ground

    Technically the logic ground is not a signal, but without it none of the other signals will operate. Basically, the logic ground acts as a reference voltage so that the electronics know which voltages are positive or negative.

    TXD - Transmitted Data

    The TXD signal carries data transmitted from your workstation to the computer or device on the other end (like a MODEM). A mark voltage is interpreted as a value of 1, while a space voltage is interpreted as a value of 0.

    RXD - Received Data

    The RXD signal carries data transmitted from the computer or device on the other end to your workstation. Like TXD, mark and space voltages are interpreted as 1 and 0, respectively.

    DCD - Data Carrier Detect

    The DCD signal is received from the computer or device on the other end of your serial cable. A space voltage on this signal line indicates that the computer or device is currently connected or on line. DCD is not always used or available.

    DTR - Data Terminal Ready

    The DTR signal is generated by your workstation and tells the computer or device on the other end that you are ready (a space voltage) or not-ready (a mark voltage). DTR is usually enabled automatically whenever you open the serial interface on the workstation.

    CTS - Clear To Send

    The CTS signal is received from the other end of the serial cable. A space voltage indicates that is alright to send more serial data from your workstation.

    CTS is usually used to regulate the flow of serial data from your workstation to the other end.

    RTS - Request To Send

    The RTS signal is set to the space voltage by your workstation to indicate that more data is ready to be sent.

    Like CTS, RTS helps to regulate the flow of data between your workstation and the computer or device on the other end of the serial cable. Most workstations leave this signal set to the space voltage all the time.

    Asynchronous Communications

    For the computer to understand the serial data coming into it, it needs some way to determine where one character ends and the next begins. This guide deals exclusively with asynchronous serial data.

    In asynchronous mode the serial data line stays in the mark (1) state until a character is transmitted. A start bit preceeds each character and is followed immediately by each bit in the character, an optional parity bit, and one or more stop bits. The start bit is always a space (0) and tells the computer that new serial data is available. Data can be sent or received at any time, thus the name asynchronous.

    Figure 1 - Asynchronous Data Transmission 

    The optional parity bit is a simple sum of the data bits indicating whether or not the data contains an even or odd number of 1 bits. With even parity, the parity bit is 0 if there is an even number of 1's in the character. With odd parity, the parity bit is 0 if there is an odd number of 1's in the data. You may also hear the terms space paritymark parity, and no parity. Space parity means that the parity bit is always 0, while mark parity means the bit is always 1. No parity means that no parity bit is present or transmitted.

    The remaining bits are called stop bits. There can be 1, 1.5, or 2 stop bits between characters and they always have a value of 1. Stop bits traditionally were used to give the computer time to process the previous character, but now only serve to synchronize the receiving computer to the incoming characters.

    Asynchronous data formats are usually expressed as "8N1", "7E1", and so forth. These stand for "8 data bits, no parity, 1 stop bit" and "7 data bits, even parity, 1 stop bit" respectively.

    What Are Full Duplex and Half Duplex?

    Full duplex means that the computer can send and receive data simultaneously - there are two separate data channels (one coming in, one going out).

    Half duplex means that the computer cannot send or receive data at the same time. Usually this means there is only a single data channel to talk over. This does not mean that any of the RS-232 signals are not used. Rather, it usually means that the communications link uses some standard other than RS-232 that does not support full duplex operation.

    Flow Control

    It is often necessary to regulate the flow of data when transferring data between two serial interfaces. This can be due to limitations in an intermediate serial communications link, one of the serial interfaces, or some storage media. Two methods are commonly used for asynchronous data.

    The first method is often called "software" flow control and uses special characters to start (XON or DC1, 021 octal) or stop (XOFF or DC3, 023 octal) the flow of data. These characters are defined in the American Standard Code for Information Interchange ("ASCII"). While these codes are useful when transferring textual information, they cannot be used when transferring other types of information without special programming.

    The second method is called "hardware" flow control and uses the RS-232 CTS and RTS signals instead of special characters. The receiver sets CTS to the space voltage when it is ready to receive more data and to the mark voltage when it is not ready. Likewise, the sender sets RTS to the space voltage when it is ready to send more data. Because hardware flow control uses a separate set of signals, it is much faster than software flow control which needs to send or receive multiple bits of information to do the same thing. CTS/RTS flow control is not supported by all hardware or operating systems.

    What Is a Break?

    Normally a receive or transmit data signal stays at the mark voltage until a new character is transferred. If the signal is dropped to the space voltage for a long period of time, usually 1/4 to 1/2 second, then a break condition is said to exist.

    A break is sometimes used to reset a communications line or change the operating mode of communications hardware like a MODEM. Chapter 3, Talking to MODEMs covers these applications in more depth.

    Synchronous Communications

    Unlike asynchronous data, synchronous data appears as a constant stream of bits. To read the data on the line, the computer must provide or receive a common bit clock so that both the sender and receiver are synchronized.

    Even with this synchronization, the computer must mark the beginning of the data somehow. The most common way of doing this is to use a data packet protocol like Serial Data Link Control ("SDLC") or High-Speed Data Link Control ("HDLC").

    Each protocol defines certain bit sequences to represent the beginning and end of a data packet. Each also defines a bit sequence that is used when there is no data. These bit sequences allow the computer see the beginning of a data packet.

    Because synchronous protocols do not use per-character synchronization bits they typically provide at least a 25% improvement in performance over asynchronous communications and are suitable for remote networking and configurations with more than two serial interfaces.

    Despite the speed advantages of synchronous communications, most RS-232 hardware does not support it due to the extra hardware and software required.

    Accessing Serial Ports

    Like all devices, UNIX provides access to serial ports via device files. To access a serial port you simply open the corresponding device file.

    Serial Port Files

    Each serial port on a UNIX system has one or more device files (files in the /dev directory) associated with it:

    Table 2 - Serial Port Device FilesSystemPort 1Port 2IRIX®/dev/ttyf1/dev/ttyf2HP-UX/dev/tty1p0/dev/tty2p0Solaris®/SunOS®/dev/ttya/dev/ttybLinux®/dev/ttyS0/dev/ttyS1Digital UNIX®/dev/tty01/dev/tty02

    Opening a Serial Port

    Since a serial port is a file, the open(2) function is used to access it. The one hitch with UNIX is that device files are usually not accessable by normal users. Workarounds include changing the access permissions to the file(s) in question, running your program as the super-user (root), or making your program set-userid so that it runs as the owner of the device file.

    For now we'll assume that the file is accessable by all users. The code to open serial port 1 on an sgi® workstation running IRIX is:

      Listing 1 - Opening a serial port.

      #include <stdio.h>   /* Standard input/output definitions */#include <string.h>  /* String function definitions */#include <unistd.h>  /* UNIX standard function definitions */#include <fcntl.h>   /* File control definitions */#include <errno.h>   /* Error number definitions */#include <termios.h> /* POSIX terminal control definitions *//* * 'open_port()' - Open serial port 1. * * Returns the file descriptor on success or -1 on error. */intopen_port(void){  int fd; /* File descriptor for the port */  fd = open("/dev/ttyf1", O_RDWR | O_NOCTTY | O_NDELAY);  if (fd == -1)  {   /*    * Could not open the port.    */    perror("open_port: Unable to open /dev/ttyf1 - ");  }  else    fcntl(fd, F_SETFL, 0);  return (fd);}

    Other systems would require the corresponding device file name, but otherwise the code is the same.

    Open Options

    You'll notice that when we opened the device file we used two other flags along with the read+write mode:

      fd = open("/dev/ttyf1", O_RDWR | O_NOCTTY | O_NDELAY);

    The O_NOCTTY flag tells UNIX that this program doesn't want to be the "controlling terminal" for that port. If you don't specify this then any input (such as keyboard abort signals and so forth) will affect your process. Programs like getty(1M/8) use this feature when starting the login process, but normally a user program does not want this behavior.

    The O_NDELAY flag tells UNIX that this program doesn't care what state the DCD signal line is in - whether the other end of the port is up and running. If you do not specify this flag, your process will be put to sleep until the DCD signal line is the space voltage.

    Writing Data to the Port

    Writing data to the port is easy - just use the write(2) system call to send data it:

      n = write(fd, "ATZ\r", 4);if (n < 0)  fputs("write() of 4 bytes failed!\n", stderr);

    The write function returns the number of bytes sent or -1 if an error occurred. Usually the only error you'll run into is EIO when a MODEM or data link drops the Data Carrier Detect (DCD) line. This condition will persist until you close the port.

    Reading Data from the Port

    Reading data from a port is a little trickier. When you operate the port in raw data mode, each read(2) system call will return however many characters are actually available in the serial input buffers. If no characters are available, the call will block (wait) until characters come in, an interval timer expires, or an error occurs. The read function can be made to return immediately by doing the following:

      fcntl(fd, F_SETFL, FNDELAY);

    The FNDELAY option causes the read function to return 0 if no characters are available on the port. To restore normal (blocking) behavior, call fcntl()without the FNDELAY option:

      fcntl(fd, F_SETFL, 0);

    This is also used after opening a serial port with the O_NDELAY option.

    Closing a Serial Port

    To close the serial port, just use the close system call:

      close(fd);

    Closing a serial port will also usually set the DTR signal low which causes most MODEMs to hang up.


    Chapter 2, Configuring the Serial Port

    This chapter discusses how to configure a serial port from C using the POSIX termios interface.

    The POSIX Terminal Interface

    Most systems support the POSIX terminal (serial) interface for changing parameters such as baud rate, character size, and so on. The first thing you need to do is include the file <termios.h>; this defines the terminal control structure as well as the POSIX control functions.

    The two most important POSIX functions are tcgetattr(3) and tcsetattr(3). These get and set terminal attributes, respectively; you provide a pointer to a termios structure that contains all of the serial options available:

    Table 3 - Termios Structure MembersMemberDescriptionc_cflagControl optionsc_lflagLine optionsc_iflagInput optionsc_oflagOutput optionsc_ccControl charactersc_ispeedInput baud (new interface)c_ospeedOutput baud (new interface)

    Control Options

    The c_cflag member controls the baud rate, number of data bits, parity, stop bits, and hardware flow control. There are constants for all of the supported configurations.
    Table 4 - Constants for the c_cflag MemberConstantDescriptionCBAUDBit mask for baud rateB00 baud (drop DTR)B5050 baudB7575 baudB110110 baudB134134.5 baudB150150 baudB200200 baudB300300 baudB600600 baudB12001200 baudB18001800 baudB24002400 baudB48004800 baudB96009600 baudB1920019200 baudB3840038400 baudB5760057,600 baudB7680076,800 baudB115200115,200 baudEXTAExternal rate clockEXTBExternal rate clockCSIZEBit mask for data bitsCS55 data bitsCS66 data bitsCS77 data bitsCS88 data bitsCSTOPB2 stop bits (1 otherwise)CREADEnable receiverPARENBEnable parity bitPARODDUse odd parity instead of evenHUPCLHangup (drop DTR) on last closeCLOCALLocal line - do not change "owner" of portLOBLKBlock job control outputCNEW_RTSCTS 
    CRTSCTSEnable hardware flow control (not supported on all platforms)

    The c_cflag member contains two options that should always be enabled, CLOCAL and CREAD. These will ensure that your program does not become the 'owner' of the port subject to sporatic job control and hangup signals, and also that the serial interface driver will read incoming data bytes.

    The baud rate constants (CBAUDB9600, etc.) are used for older interfaces that lack the c_ispeed and c_ospeed members. See the next section for information on the POSIX functions used to set the baud rate.

    Never initialize the c_cflag (or any other flag) member directly; you should always use the bitwise AND, OR, and NOT operators to set or clear bits in the members. Different operating system versions (and even patches) can and do use the bits differently, so using the bitwise operators will prevent you from clobbering a bit flag that is needed in a newer serial driver.

    Setting the Baud Rate

    The baud rate is stored in different places depending on the operating system. Older interfaces store the baud rate in the c_cflag member using one of the baud rate constants in table 4, while newer implementations provide the c_ispeed and c_ospeed members that contain the actual baud rate value.

    The cfsetospeed(3) and cfsetispeed(3) functions are provided to set the baud rate in the termios structure regardless of the underlying operating system interface. Typically you'd use the following code to set the baud rate:

      Listing 2 - Setting the baud rate.

      struct termios options;/* * Get the current options for the port... */tcgetattr(fd, &options);/* * Set the baud rates to 19200... */cfsetispeed(&options, B19200);cfsetospeed(&options, B19200);/* * Enable the receiver and set local mode... */options.c_cflag |= (CLOCAL | CREAD);/* * Set the new options for the port... */tcsetattr(fd, TCSANOW, &options);

    The tcgetattr(3) function fills the termios structure you provide with the current serial port configuration. After we set the baud rates and enable local mode and serial data receipt, we select the new configuration using tcsetattr(3). The TCSANOW constant specifies that all changes should occur immediately without waiting for output data to finish sending or input data to finish receiving. There are other constants to wait for input and output to finish or to flush the input and output buffers.

    Most systems do not support different input and output speeds, so be sure to set both to the same value for maximum portability.

    Table 5 - Constants for tcsetattrConstantDescriptionTCSANOWMake changes now without waiting for data to completeTCSADRAINWait until everything has been transmittedTCSAFLUSHFlush input and output buffers and make the change

    Setting the Character Size

    Unlike the baud rate, there is no convienience function to set the character size. Instead you must do a little bitmasking to set things up. The character size is specified in bits:

      options.c_cflag &= ~CSIZE; /* Mask the character size bits */options.c_cflag |= CS8;    /* Select 8 data bits */

    Setting Parity Checking

    Like the character size you must manually set the parity enable and parity type bits. UNIX serial drivers support even, odd, and no parity bit generation. Space parity can be simulated with clever coding.

    • No parity (8N1):
      options.c_cflag &= ~PARENBoptions.c_cflag &= ~CSTOPBoptions.c_cflag &= ~CSIZE;options.c_cflag |= CS8;
    • Even parity (7E1):
      options.c_cflag |= PARENBoptions.c_cflag &= ~PARODDoptions.c_cflag &= ~CSTOPBoptions.c_cflag &= ~CSIZE;options.c_cflag |= CS7;
    • Odd parity (7O1):
      options.c_cflag |= PARENBoptions.c_cflag |= PARODDoptions.c_cflag &= ~CSTOPBoptions.c_cflag &= ~CSIZE;options.c_cflag |= CS7;
    • Space parity is setup the same as no parity (7S1):
      options.c_cflag &= ~PARENBoptions.c_cflag &= ~CSTOPBoptions.c_cflag &= ~CSIZE;options.c_cflag |= CS8;

    Setting Hardware Flow Control

    Some versions of UNIX support hardware flow control using the CTS (Clear To Send) and RTS (Request To Send) signal lines. If the CNEW_RTSCTS or CRTSCTSconstants are defined on your system then hardware flow control is probably supported. Do the following to enable hardware flow control:

      options.c_cflag |= CNEW_RTSCTS;    /* Also called CRTSCTS */

    Similarly, to disable hardware flow control:

      options.c_cflag &= ~CNEW_RTSCTS;

    Local Options

    The local modes member c_lflag controls how input characters are managed by the serial driver. In general you will configure the c_lflag member forcanonical or raw input.

    Table 6 - Constants for the c_lflag MemberConstantDescriptionISIGEnable SIGINTR, SIGSUSP, SIGDSUSP, and SIGQUIT signalsICANONEnable canonical input (else raw)XCASEMap uppercase \lowercase (obsolete)ECHOEnable echoing of input charactersECHOEEcho erase character as BS-SP-BSECHOKEcho NL after kill characterECHONLEcho NLNOFLSHDisable flushing of input buffers after interrupt or quit charactersIEXTENEnable extended functionsECHOCTLEcho control characters as ^char and delete as ~?ECHOPRTEcho erased character as character erasedECHOKEBS-SP-BS entire line on line killFLUSHOOutput being flushedPENDINRetype pending input at next read or input charTOSTOPSend SIGTTOU for background output

    Choosing Canonical Input

    Canonical input is line-oriented. Input characters are put into a buffer which can be edited interactively by the user until a CR (carriage return) or LF (line feed) character is received.

    When selecting this mode you normally select the ICANONECHO, and ECHOE options:

      options.c_lflag |= (ICANON | ECHO | ECHOE);

    Choosing Raw Input

    Raw input is unprocessed. Input characters are passed through exactly as they are received, when they are received. Generally you'll deselect theICANONECHOECHOE, and ISIG options when using raw input:

      options.c_lflag &= ~(ICANON | ECHO | ECHOE | ISIG);

    A Note About Input Echo

    Never enable input echo (ECHO, ECHOE) when sending commands to a MODEM or other computer that is echoing characters, as you will generate a feedback loop between the two serial interfaces!

    Input Options

    The input modes member c_iflag controls any input processing that is done to characters received on the port. Like the c_cflag field, the final value stored in c_iflag is the bitwise OR of the desired options.

    Table 7 - Constants for the c_iflag MemberConstantDescriptionINPCKEnable parity checkIGNPARIgnore parity errorsPARMRKMark parity errorsISTRIPStrip parity bitsIXONEnable software flow control (outgoing)IXOFFEnable software flow control (incoming)IXANYAllow any character to start flow againIGNBRKIgnore break conditionBRKINTSend a SIGINT when a break condition is detectedINLCRMap NL to CRIGNCRIgnore CRICRNLMap CR to NLIUCLCMap uppercase to lowercaseIMAXBELEcho BEL on input line too long

    Setting Input Parity Options

    You should enable input parity checking when you have enabled parity in the c_cflag member (PARENB). The revelant constants for input parity checking are INPCKIGNPARPARMRK , and ISTRIP. Generally you will select INPCK and ISTRIP to enable checking and stripping of the parity bit:

      options.c_iflag |= (INPCK | ISTRIP);

    IGNPAR is a somewhat dangerous option that tells the serial driver to ignore parity errors and pass the incoming data through as if no errors had occurred. This can be useful for testing the quality of a communications link, but in general is not used for practical reasons.

    PARMRK causes parity errors to be 'marked' in the input stream using special characters. If IGNPAR is enabled, a NUL character (000 octal) is sent to your program before every character with a parity error. Otherwise, a DEL (177 octal) and NUL character is sent along with the bad character.

    Setting Software Flow Control

    Software flow control is enabled using the IXONIXOFF , and IXANY constants:

      options.c_iflag |= (IXON | IXOFF | IXANY);

    To disable software flow control simply mask those bits:

      options.c_iflag &= ~(IXON | IXOFF | IXANY);

    The XON (start data) and XOFF (stop data) characters are defined in the c_cc array described below.

    Output Options

    The c_oflag member contains output filtering options. Like the input modes, you can select processed or raw data output.

    Table 8 - Constants for the c_oflag MemberConstantDescriptionOPOSTPostprocess output (not set = raw output)OLCUCMap lowercase to uppercaseONLCRMap NL to CR-NLOCRNLMap CR to NLNOCRNo CR output at column 0ONLRETNL performs CR functionOFILLUse fill characters for delayOFDELFill character is DELNLDLYMask for delay time needed between linesNL0No delay for NLsNL1Delay further output after newline for 100 millisecondsCRDLYMask for delay time needed to return carriage to left columnCR0No delay for CRsCR1Delay after CRs depending on current column positionCR2Delay 100 milliseconds after sending CRsCR3Delay 150 milliseconds after sending CRsTABDLYMask for delay time needed after TABsTAB0No delay for TABsTAB1Delay after TABs depending on current column positionTAB2Delay 100 milliseconds after sending TABsTAB3Expand TAB characters to spacesBSDLYMask for delay time needed after BSsBS0No delay for BSsBS1Delay 50 milliseconds after sending BSsVTDLYMask for delay time needed after VTsVT0No delay for VTsVT1Delay 2 seconds after sending VTsFFDLYMask for delay time needed after FFsFF0No delay for FFsFF1Delay 2 seconds after sending FFs

    Choosing Processed Output

    Processed output is selected by setting the OPOST option in the c_oflag member:

      options.c_oflag |= OPOST;

    Of all the different options, you will only probably use the ONLCR option which maps newlines into CR-LF pairs. The rest of the output options are primarily historic and date back to the time when line printers and terminals could not keep up with the serial data stream!

    Choosing Raw Output

    Raw output is selected by resetting the OPOST option in the c_oflag member:

      options.c_oflag &= ~OPOST;

    When the OPOST option is disabled, all other option bits in c_oflag are ignored.

    Control Characters

    The c_cc character array contains control character definitions as well as timeout parameters. Constants are defined for every element of this array.

    Table 9 - Control Characters in the c_cc MemberConstantDescriptionKeyVINTRInterruptCTRL-CVQUITQuitCTRL-ZVERASEEraseBackspace (BS)VKILLKill-lineCTRL-UVEOFEnd-of-fileCTRL-DVEOLEnd-of-lineCarriage return (CR)VEOL2Second end-of-lineLine feed (LF)VMINMinimum number of characters to readVTIMETime to wait for data (tenths of seconds)

    Setting Software Flow Control Characters

    The VSTART and VSTOP elements of the c_cc array contain the characters used for software flow control. Normally they should be set to DC1 (021 octal) and DC3 (023 octal) which represent the ASCII standard XON and XOFF characters.

    Setting Read Timeouts

    UNIX serial interface drivers provide the ability to specify character and packet timeouts. Two elements of the c_cc array are used for timeouts: VMINand VTIMETimeouts are ignored in canonical input mode or when the NDELAY option is set on the file via open or fcntl.

    VMIN specifies the minimum number of characters to read. If it is set to 0, then the VTIME value specifies the time to wait for every character read. Note that this does not mean that a read call for N bytes will wait for N characters to come in. Rather, the timeout will apply to the first character and the read call will return the number of characters immediately available (up to the number you request).

    If VMIN is non-zero, VTIME specifies the time to wait for the first character read. If a character is read within the time given, any read will block (wait) until all VMIN characters are read. That is, once the first character is read, the serial interface driver expects to receive an entire packet of characters (VMIN bytes total). If no character is read within the time allowed, then the call to read returns 0. This method allows you to tell the serial driver you need exactly N bytes and any read call will return 0 or N bytes. However, the timeout only applies to the first character read, so if for some reason the driver misses one character inside the N byte packet then the read call could block forever waiting for additional input characters.

    VTIME specifies the amount of time to wait for incoming characters in tenths of seconds. If VTIME is set to 0 (the default), reads will block (wait) indefinitely unless the NDELAY option is set on the port with open or fcntl.


    Chapter 3, MODEM Communications

    This chapter covers the basics of dialup telephone Modulator/Demodulator (MODEM) communications. Examples are provided for MODEMs that use the defacto standard "AT" command set.

    What Is a MODEM?

    MODEMs are devices that modulate serial data into frequencies that can be transferred over an analog data link such as a telephone line or cable TV connection. A standard telephone MODEM converts serial data into tones that can be passed over the phone lines; because of the speed and complexity of the conversion these tones sound more like loud screeching if you listen to them.

    Telephone MODEMs are available today that can transfer data across a telephone line at nearly 53,000 bits per second, or 53kbps. In addition, most MODEMs use data compression technology that can increase the bit rate to well over 100kbps on some types of data.

    Communicating With a MODEM

    The first step in communicating with a MODEM is to open and configure the port for raw input:

      Listing 3 - Configuring the port for raw input.

      int            fd;struct termios options;/* open the port */fd = open("/dev/ttyf1", O_RDWR | O_NOCTTY | O_NDELAY);fcntl(fd, F_SETFL, 0);/* get the current options */tcgetattr(fd, &options);/* set raw input, 1 second timeout */options.c_cflag     |= (CLOCAL | CREAD);options.c_lflag     &= ~(ICANON | ECHO | ECHOE | ISIG);options.c_oflag     &= ~OPOST;options.c_cc[VMIN]  = 0;options.c_cc[VTIME] = 10;/* set the options */tcsetattr(fd, TCSANOW, &options);

    Next you need to establish communications with the MODEM. The best way to do this is by sending the "AT" command to the MODEM. This also allows smart MODEMs to detect the baud you are using. When the MODEM is connected correctly and powered on it will respond with the response "OK".

      Listing 4 - Initializing the MODEM.

      int                  /* O - 0 = MODEM ok, -1 = MODEM bad */init_modem(int fd)   /* I - Serial port file */{  char buffer[255];  /* Input buffer */  char *bufptr;      /* Current char in buffer */  int  nbytes;       /* Number of bytes read */  int  tries;        /* Number of tries so far */  for (tries = 0; tries < 3; tries ++)  {   /* send an AT command followed by a CR */    if (write(fd, "AT\r", 3) < 3)      continue;   /* read characters into our string buffer until we get a CR or NL */    bufptr = buffer;    while ((nbytes = read(fd, bufptr, buffer + sizeof(buffer) - bufptr - 1)) > 0)    {      bufptr += nbytes;      if (bufptr[-1] == '\n' || bufptr[-1] == '\r')        break;    }   /* nul terminate the string and see if we got an OK response */    *bufptr = '\0';    if (strncmp(buffer, "OK", 2) == 0)      return (0);  }  return (-1);}

    Standard MODEM Commands

    Most MODEMs support the "AT" command set, so called because each command starts with the "AT" characters. Each command is sent with the "AT" characters starting in the first column followed by the specific command and a carriage return (CR, 015 octal). After processing the command the MODEM will reply with one of several textual messages depending on the command.

    ATD - Dial A Number

    The ATD command dials the specified number. In addition to numbers and dashes you can specify tone ("T") or pulse ("P") dialing, pause for one second (","), and wait for a dialtone ("W"):

      ATDT 555-1212ATDT 18008008008W1234,1,1234ATD T555-1212WP1234

    The MODEM will reply with one of the following messages:

      NO DIALTONEBUSYNO CARRIERCONNECTCONNECT baud

    ATH - Hang Up

    The ATH command causes the MODEM to hang up. Since the MODEM must be in "command" mode you probably won't use it during a normal phone call.

    Most MODEMs will also hang up if DTR is dropped; you can do this by setting the baud to 0 for at least 1 second. Dropping DTR also returns the MODEM to command mode.

    After a successful hang up the MODEM will reply with "NO CARRIER". If the MODEM is still connected the "CONNECT" or "CONNECT baud" message will be sent.

    ATZ - Reset MODEM

    The ATZ command resets the MODEM. The MODEM will reply with the string "OK".

    Common MODEM Communication Problems

    First and foremost, don't forget to disable input echoing. Input echoing will cause a feedback loop between the MODEM and computer.

    Second, when sending MODEM commands you must terminate them with a carriage return (CR) and not a newline (NL). The C character constant for CR is "\r".

    Finally, when dealing with a MODEM make sure you use a baud that the MODEM supports. While many MODEMs do auto-baud detection, some have limits (19.2kbps is common) that you must observe.


    Chapter 4, Advanced Serial Programming

    This chapter covers advanced serial programming techniques using the ioctl(2) and select(2) system calls.

    Serial Port IOCTLs

    In Chapter 2, Configuring the Serial Port we used the tcgetattr and tcsetattr functions to configure the serial port. Under UNIX these functions use the ioctl(2) system call to do their magic.

    The ioctl system call takes three arguments:

      int ioctl(int fd, int request, ...);

    The fd argument specifies the serial port file descriptor. The request argument is a constant defined in the <termios.h> header file and is typically one of the following:

    Table 10 - IOCTL Requests for Serial PortsRequestDescriptionPOSIX FunctionTCGETSGets the current serial port settings.tcgetattrTCSETSSets the serial port settings immediately.tcsetattr(fd, TCSANOW, &options)TCSETSFSets the serial port settings after flushing the input and output buffers.tcsetattr(fd, TCSANOW, &options)TCSETSWSets the serial port settings after allowing the input and output buffers to drain/empty.tcsetattr(fd, TCSANOW, &options)TCSBRKSends a break for the given time.tcsendbreak, tcdrainTCXONCControls software flow control.tcflowTCFLSHFlushes the input and/or output queue.tcflushTIOCMGETReturns the state of the "MODEM" bits.NoneTIOCMSETSets the state of the "MODEM" bits.NoneFIONREADReturns the number of bytes in the input buffer.None

    Getting the Control Signals

    The TIOCMGET ioctl gets the current "MODEM" status bits, which consist of all of the RS-232 signal lines except RXD and TXD:

    Table 11 - Control Signal ConstantsConstantDescriptionTIOCM_LEDSR (data set ready/line enable)TIOCM_DTRDTR (data terminal ready)TIOCM_RTSRTS (request to send)TIOCM_STSecondary TXD (transmit)TIOCM_SRSecondary RXD (receive)TIOCM_CTSCTS (clear to send)TIOCM_CARDCD (data carrier detect)TIOCM_CDSynonym for TIOCM_CARTIOCM_RNGRNG (ring)TIOCM_RISynonym for TIOCM_RNGTIOCM_DSRDSR (data set ready)

    To get the status bits, call ioctl with a pointer to an integer to hold the bits:

      Listing 5 - Getting the MODEM status bits.

      #include <unistd.h>#include <termios.h>int fd;int status;ioctl(fd, TIOCMGET, &status);

    Setting the Control Signals

    The TIOCMSET ioctl sets the "MODEM" status bits defined above. To drop the DTR signal you can do:

      Listing 6 - Dropping DTR with the TIOCMSET ioctl.

      #include <unistd.h>#include <termios.h>int fd;int status;ioctl(fd, TIOCMGET, &status);status &= ~TIOCM_DTR;ioctl(fd, TIOCMSET, status);

    The bits that can be set depend on the operating system, driver, and modes in use. Consult your operating system documentation for more information.

    Getting the Number of Bytes Available

    The FIONREAD ioctl gets the number of bytes in the serial port input buffer. As with TIOCMGET you pass in a pointer to an integer to hold the number of bytes:

      Listing 7 - Getting the number of bytes in the input buffer.

      #include <unistd.h>#include <termios.h>int fd;int bytes;ioctl(fd, FIONREAD, &bytes);

    This can be useful when polling a serial port for data, as your program can determine the number of bytes in the input buffer before attempting a read.

    Selecting Input from a Serial Port

    While simple applications can poll or wait on data coming from the serial port, most applications are not simple and need to handle input from multiple sources.

    UNIX provides this capability through the select(2) system call. This system call allows your program to check for input, output, or error conditions on one or more file descriptors. The file descriptors can point to serial ports, regular files, other devices, pipes, or sockets. You can poll to check for pending input, wait for input indefinitely, or timeout after a specific amount of time, making the select system call extremely flexible.

    Most GUI Toolkits provide an interface to select; we will discuss the X Intrinsics ("Xt") library later in this chapter.

    The SELECT System Call

    The select system call accepts 5 arguments:

      int select(int max_fd, fd_set *input, fd_set *output, fd_set *error,           struct timeval *timeout);

    The max_fd argument specifies the highest numbered file descriptor in the inputoutput, and error sets. The inputoutput, and error arguments specify sets of file descriptors for pending input, output, or error conditions; specify NULL to disable monitoring for the corresponding condition. These sets are initialized using three macros:

      FD_ZERO(fd_set);FD_SET(fd, fd_set);FD_CLR(fd, fd_set);

    The FD_ZERO macro clears the set entirely. The FD_SET and FD_CLR macros add and remove a file descriptor from the set, respectively.

    The timeout argument specifies a timeout value which consists of seconds (timeout.tv_sec) and microseconds (timeout.tv_usec ). To poll one or more file descriptors, set the seconds and microseconds to zero. To wait indefinitely specify NULL for the timeout pointer.

    The select system call returns the number of file descriptors that have a pending condition, or -1 if there was an error.

    Using the SELECT System Call

    Suppose we are reading data from a serial port and a socket. We want to check for input from either file descriptor, but want to notify the user if no data is seen within 10 seconds. To do this we'll need to use the select system call:

      Listing 8 - Using SELECT to process input from more than one source.

      #include <unistd.h>#include <sys/types.h>#include <sys/time.h>#include <sys/select.h>int            n;int            socket;int            fd;int            max_fd;fd_set         input;struct timeval timeout;/* Initialize the input set */FD_ZERO(input);FD_SET(fd, input);FD_SET(socket, input);max_fd = (socket > fd ? socket : fd) + 1;/* Initialize the timeout structure */timeout.tv_sec  = 10;timeout.tv_usec = 0;/* Do the select */n = select(max_fd,  NULL, NULL, ;/* See if there was an error */if (n 0)  perror("select failed");else if (n == 0)  puts("TIMEOUT");else{  /* We have input */  if (FD_ISSET(fd, input))    process_fd();  if (FD_ISSET(socket, input))    process_socket();}

    You'll notice that we first check the return value of the select system call. Values of 0 and -1 yield the appropriate warning and error messages. Values greater than 0 mean that we have data pending on one or more file descriptors.

    To determine which file descriptor(s) have pending input, we use the FD_ISSET macro to test the input set for each file descriptor. If the file descriptor flag is set then the condition exists (input pending in this case) and we need to do something.

    Using SELECT with the X Intrinsics Library

    The X Intrinsics library provides an interface to the select system call via the XtAppAddInput(3x) and XtAppRemoveInput(3x) functions:

      int XtAppAddInput(XtAppContext context, int fd, int mask,                  XtInputProc proc, XtPointer data);void XtAppRemoveInput(XtAppContext context, int input);

    The select system call is used internally to implement timeouts, work procedures, and check for input from the X server. These functions can be used with any Xt-based toolkit including Xaw, Lesstif, and Motif.

    The proc argument to XtAppAddInput specifies the function to call when the selected condition (e.g. input available) exists on the file descriptor. In the previous example you could specify the process_fd or process_socket functions.

    Because Xt limits your access to the select system call, you'll need to implement timeouts through another mechanism, probably via XtAppAddTimeout(3x).


    Appendix A, Pinouts

    This appendix provides pinout information for many of the common serial ports you will find.

    RS-232 Pinouts

    RS-232 comes in three flavors (A, B, C) and uses a 25-pin D-Sub connector:

    Figure 2 - RS-232 Connector 

    Table 12 - RS-232 SignalsPinDescriptionPinDescription1Earth Ground14Secondary TXD2TXD - Transmitted Data15Transmit Clock3RXD - Received Data16Secondary RXD4RTS - Request To Send17Receiver Clock5CTS - Clear To Send18Unassigned6DSR - Data Set Ready19Secondary RTS7GND - Logic Ground20DTR - Data Terminal Ready8DCD - Data Carrier Detect21Signal Quality Detect9Reserved22Ring Detect10Reserved23Data Rate Select11Unassigned24Transmit Clock12Secondary DCD25Unassigned13Secondary CTS

    RS-422 Pinouts

    RS-422 also uses a 25-pin D-Sub connector, but with differential signals:

    Figure 3 - RS-422 Connector 

    Table 13 - RS-422 SignalsPinDescriptionPinDescription1Earth Ground14TXD+2TXD- - Transmitted Data15Transmit Clock-3RXD- - Received Data16RXD+4RTS- - Request To Send17Receiver Clock-5CTS- - Clear To Send18Unassigned6DSR - Data Set Ready19RTS+7GND - Logic Ground20DTR- - Data Terminal Ready8DCD- - Data Carrier Detect21Signal Quality Detect9Reserved22Unassigned10Reserved23DTR+11Unassigned24Transmit Clock+12DCD+25Receiver Clock+13CTS+

    RS-574 (IBM PC/AT) Pinouts

    The RS-574 interface is used exclusively by PC manufacturers and uses a 9-pin male D-Sub connector:

    Figure 4 - RS-574 Connector 

    Table 14 - RS-574 (IBM PC/AT) SignalsPinDescriptionPinDescription1DCD - Data Carrier Detect6Data Set Ready2RXD - Received Data7RTS - Request To Send3TXD - Transmitted Data8CTS - Clear To Send4DTR - Data Terminal Ready9Ring Detect5GND - Logic Ground

    SGI Pinouts

    Older SGI equipment uses a 9-pin female D-Sub connector. Unlike RS-574, the SGI pinouts nearly match those of RS-232:

    Figure 5 - SGI 9-Pin Connector 

    Table 15 - SGI 9-Pin DSUB SignalsPinDescriptionPinDescription1Earth Ground6DSR - Data Set Ready2TXD - Transmitted Data7GND - Logic Ground3RXD - Received Data8DCD - Data Carrier Detect4RTS - Request To Send9DTR - Data Terminal Ready5CTS - Clear To Send

    The SGI Indigo, Indigo2, and Indy workstations use the Apple 8-pin MiniDIN connector for their serial ports:

    Figure 6 - SGI 8-Pin Connector 

    Table 16 - SGI 8-Pin MiniDIN SignalsPinDescriptionPinDescription1DTR - Data Terminal Ready5RXD - Received Data2CTS - Clear To Send6RTS - Request To Send3TXD - Transmitted Data7DCD - Data Carrier Detect4GND - Logic Ground8GND - Logic Ground

    Appendix B, ASCII Control Codes

    This chapter lists the ASCII control codes and their names.

    Control Codes

    The following ASCII characters are used for control purposes:
    Table 17 - ASCII Control CodesNameBinaryOctalDecimalHexadecimal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