A RAID controller enables RAID by logically linking multiple HDD units. All the HDD units that are used for constructing RAID are not necessarily new or data in the HDD units have not necessarily been deleted. The initialization function performs initialization processing for the HDD units that are used for constructing RAID. Three types of RAID controller initialization are available, normal initialization (NI), fast initialization (FI), and background initialization (BGI).
Normal initialization and fast initialization
In normal initialization, zero data is written to all the HDD areas that configure the disk array. Since the information in the HDD is cleared to 0, the entire invalid data that has been originally stored in the HDD can be deleted. Since all zero data is recorded, the consistency of the parity information is also restored.
Fast initialization (FI)
In fast initialization, zero data is written only in the top sections of the HDD units that form the disk array. The OS install information and partition information can be cleared. Since shorter processing than normal initialization is required, processing can be advanced to the next task quickly. However, as some areas are not initialized, consistency of all the disk array areas is not established.
Background initialization (BGI)
When fast initialization is executed, normal initialization is interrupted, or initialization is not executed for the disk array, the disk array contains uninitialized areas. Background initialization is the function that matches the parities for all the uninitialized areas in background.
Initialization correspondence
LSI RAID Controllers
Fast Initialization = ON <Fast Initialization>
Zero is written to the first several blocks of the logical drive.
Fast Initialization = OFF <Normal Initialization>
Zero is written to the entire logical drive. At completion of total initialization, initialization ompletion history information is saved in DAC and HDD.
Background initialization
When the RAID configuration level is 5, involving five more HDD units and NvRAM of the DAC does not contain initialization completion history information, BGI is executed. For the configuration without BGI execution, parity modification must be performed for the uninitialized areas using the data consistency checking function.
- [转发][纯记录]raid组的初始化详解
- raid 3108 的初始化
- Raid的一些记录
- 硬RAID、软RAID的区别详解
- 硬RAID、软RAID的区别详解
- RAID的后台初始化 Background Initialization
- raid记录
- 关于服务器raid的一个记录
- 详解RAID——几种常见的RAID形式
- RAID磁盘阵列详解以及软RAID的实施部署
- RAID详解
- RAID详解
- RAID详解
- RAID 详解
- RAID详解
- RAID详解
- RAID详解
- 记录xutils的初始化
- Leet Code 10 Regular Expression Matching
- spring配置详解
- 剑指offer 牛客网 。。。
- HTTP协议
- go 解析XML 设置缺省att的默认值
- [转发][纯记录]raid组的初始化详解
- Selection sort 选择排序
- PHP调试网页出现乱码解决方法!
- OpenCV视频进度播放控制
- opengl学习笔记(2)
- pl_sql
- 得到view的信息以及 view绘制流程解析
- JAVA高并发学习笔记(四) 无锁
- check tech