-bash-3.2# fmadm faulty
--------------- ------------------------------------  -------------- ---------
TIME            EVENT-ID                              MSG-ID         SEVERITY
--------------- ------------------------------------  -------------- ---------
Jun 04 20:10:17 b75b3279-ec5e-6c1a-8cec-f679bc4dc4f0  PCIEX-8000-0A  Critical

Fault class : fault.io.pciex.device-interr
Affects     : dev:////pci@0,0/pci8086,29c1@1/pci8086,115e@0
                  faulted and taken out of service
FRU         : "MB" (hc:///component=motherboard)
                  faulty

Description : A problem was detected for a PCIEX device.
              Refer to http://sun.com/msg/PCIEX-8000-0A for more information.

Response    : One or more device instances may be disabled

Impact      : Loss of services provided by the device instances associated with
              this fault

Action      : Schedule a repair procedure to replace the affected device.  Use
              fmdump -v -u <EVENT_ID> to identify the device or contact Sun for
              support.

--------------- ------------------------------------  -------------- ---------
TIME            EVENT-ID                              MSG-ID         SEVERITY
--------------- ------------------------------------  -------------- ---------
Jun 04 20:09:18 61eb4b03-9def-635d-ba3d-ef5ac0401db8  PCIEX-8000-0A  Critical

Fault class : fault.io.pciex.device-interr
Affects     : dev:////pci@0,0/pci8086,29c1@1/pci8086,115e@0,1
                  faulted and taken out of service
FRU         : "MB" (hc:///component=motherboard)
                  faulty

Description : A problem was detected for a PCIEX device.
              Refer to http://sun.com/msg/PCIEX-8000-0A for more information.

Response    : One or more device instances may be disabled

Impact      : Loss of services provided by the device instances associated with
              this fault

Action      : Schedule a repair procedure to replace the affected device.  Use
              fmdump -v -u <EVENT_ID> to identify the device or contact Sun for
              support.

-bash-3.2# fmadm repair b75b3279-ec5e-6c1a-8cec-f679bc4dc4f0
fmadm: recorded repair to b75b3279-ec5e-6c1a-8cec-f679bc4dc4f0
-bash-3.2# fmadm repair 61eb4b03-9def-635d-ba3d-ef5ac0401db8
fmadm: recorded repair to 61eb4b03-9def-635d-ba3d-ef5ac0401db8
-bash-3.2# fmadm faulty
-bash-3.2# reboot