TMS320F28335: Possible Incorrect Operation of XINTF Module After Power Up

来源:互联网 发布:photo shop cs3 mac版 编辑:程序博客网 时间:2024/05/18 04:38

Failure Description:TMS320F28335would be hang-up occasionally if accessing to XINTF memory, when Hollysys teststhe third version PCBA. This issue can be found from sprz272k.pdf.

Revision(s) Affected:0, A

Details:TheXINTF module may not get reset properly upon power up. When this happens,

accesses to XINTFaddresses may cause the CPU to hang. This issue occurs only upon

power up. It does nothappen for other resets such as a reset initiated by the watchdog

or an external (warm) reset using the XRS pin.

Workaround:Aftercoming out of reset, software should force a watchdog (WD) reset if WDFLAG = 0 inthe WDCR register. WDFLAG = 0 implies that an external reset occurred, forexample, a power-on reset. After exiting the WD reset, WDFLAG will be 1. Inthis case, software should clear the WDFLAG bit before continuing normal codeexecution. This issue affects only the XINTF module.

 

Reference code
   EALLOW;
   if(!(SysCtrlRegs.WDCR &0x0080)) // if there is a watchdog reset

   {
     SysCtrlRegs.WDCR = 0x00A8; // enable watchdog 
     SysCtrlRegs.WDCR = 0x0000; // reset
   }
   SysCtrlRegs.WDCR = 0x00E8;//disable watchdog
   EDIS;